SRNE 5kW 48v Hybrid Off Grid Inverter with MPPT Solar Charge Controller HFP4850S80145 with Parallel Function
products formPRODUCTS
| SRNE 5kW 48v Hybrid Off Grid inverter with Parallel Function HFP4850S80145 Sepecification | |||
| Model | HFP4850S80-145 5KW | HFP4850U80-145 5KW | |
| Permitted parallel number | 1~6 | 1~6 | |
| Rated input voltage | 220Vac/230Vac | 110/120Vac | |
| Input voltage range | (170Vac~280Vac) ±2%;(90Vac-280Vac) ±2% | (90Vac-140Vac) ±2% | |
| Frequency | 50Hz/ 60Hz (auto-sensing) | ||
| Overload/short circuit protection | Circuit breaker | ||
| Conversion time (bypass and inverter) | 10ms (Typical value) | ||
| AC reverse protection | yes | ||
| Maximum bypass overload current | 30A | 40A | |
| Inverting mode | |||
| Output voltage waveform | Pure sine wave | ||
| Rated output power(VA) | 5000 | 5000 | |
| Rated output power(W) | 5000 | 5000 | |
| Power factor | 1 | ||
| Rated output voltage (Vac) | 230Vac | 120Vac | |
| Peak power | 10000VA | 10000VA | |
| Loaded motor capacity | 3HP | 3HP | |
| Output short-circuit protection | Breaker | ||
| Specification of bypass breaker | 40A | ||
| Rated battery input voltage | 48V (minimum start voltage 44V) | ||
| Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage | ||
| recovery... settable on LCD screen) | |||
| Power saving mode | Load ≤50W | ||
| AC charge | |||
| Battery type | Lead acid or lithium battery | ||
| Maximum charge current | 0-60A | 0-60A | |
| Charge current error | ±3Adc | ||
| Charge voltage range | 20~33Vdc | ||
| Short-circuit protection | Breaker and blown fuse | ||
| Breaker specification | 40A | ||
| Overcharge protection | Alarm and turn off charging after 1 minute | ||
| Solar charge | |||
| Maximum PV opencircuit voltage | 145Vdc | ||
| PV operation voltage range | 60-145Vdc | ||
| MPPT voltage range | 60-115Vdc | ||
| Battery voltage range | 40-60Vdc | ||
| Maximum output power | 4400W | ||
| Charge current range of solar energy (settable) | 80A | ||
| Charge short-circuit protection | Blown fuse | ||
| Wiring protection | Reverse polarity protection | ||
| Hybrid charging Max charger current specifications (AC charger+PV charger) | |||
| Max charger current(can be | 0-140A | 0-140A | |
| set) | |||
| Authentication specification | |||
| Specification authentication | CE(IEC 62109-1) | CE(IEC62109-1)/CETL(UL 1741 C22.2 NO.107.1) | |
| EMC authentication grade | EN61000,C2 | ||
| Communication interface | USB/RS485 (WiFi/GPRS)/dry node control | ||
| Dimension (L*W*D) | 426mm*322mm*124mm | ||
| Weight (kg) | 10.8KG | ||
products DESCRIPTIONPRODUCTS
48V/5KW Off Grid Solar Inverter
Model Number: HFP4850S80-145
Max. PV Input Voltage:145Vdc
Output Voltage:230VAC
Output Frequency:50Hz/ 60Hz
Size:338*430*135mm
Weight:12 kgs
AC Charge Current:60A
Max PV solar charge current:80A