| DEYE SPLIT PHASE INVERTER SPCIFICATION | ||
| Model | SUN-15K-SG01LP2-US-AM3-P | SUN-18K-SG01LP2-US-AM3-P |
| Battery Input Data | ||
| Battery Type | Lead-acid or Lithium-ion | |
| Battery Voltage Range (V) | 40-60 | |
| Max. Charging Current (A) | 275 | 350 |
| Max. Discharging Current (A) | 275 | 350 |
| Charging Strategy for Li-Ion Battery | Self-adaptation to BMS | |
| Number of Battery Input | 2 | |
| PV String Input Data | ||
| Max. PV Input Power (W) | 24000 | 28800 |
| Max. PV Input Voltage (V) | 500 | |
| Start-up Voltage (V) | 125 | |
| MPPT Voltage Range (V) | 150-425 | |
| Rated PV Input Voltage (V) | 370 | |
| Max. Operating PV Input Current (A) | 36+36+36 | |
| Max. Input Short-Circuit Current (A) | 54+54+54 | |
| No. of MPP Trackers/No. of Strings MPP Tracker | 3/2+2+2 | |
| AC Input/Output Data | ||
| Rated AC Input/Output Active Power (W) | 15000 | 18000 |
| Max. AC Input/Output Apparent Power (VA) | 15000 | 18000 |
| Rated AC Input/Output Current (A) | 62.5 | 75 |
| Max. AC Input/Output Current (A) | 62.5 | 75 |
| Max. Continuous AC Passthrough (grid to load) (A) | 200 | |
| Peak Power (off-grid) (W) | 2 times of rated power, 10s | |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |
| Rated Input/Output Voltage/Range (V) | 120/240; 208 0.88Un-1.1Un | |
| Rated Input/Output Grid Frequency/Range(Hz) | 60/55-65 | |
| Grid Connection Form | 2L+N+PE | |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | |
| DC Injection Current | <0.5% In | |
| Efficiency | ||
| Max. Efficiency | 97.6% | |
| Euro Efficiency | 96.5% | |
| MPPT Efficiency | >99% | |
| Equipment Protection | ||
| Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | |
| Surge Protection Level | TYPE II(DC), TYPE II(AC) | |
| Interface | ||
| LCD/LED Display | LCD | |
| Communication Interface | WIFI,RS485 | |
| General Data | ||
| Operating Temperature Range (℃) | -40 to +60°C, >45°C Derating | |
| Permissible Ambient Humidity | 0-100% | |
| Permissible Altitude | 3000m | |
| Noise (dB) | <55 | |
| Ingress Protection(IP) Rating | TYPE 3R | |
| Inverter Topology | Non-Isolated | |
| Over Voltage Category | OVC II(DC), OVC III(AC) | |
| Cabinet Size (Wxd-hxD mm) | 464×863×282 (Excluding Connectors and Brackets) | |
| Weight (kg) | 61.5 | |
| Type of Cooling | Intelligent Air Cooling | |
| Warranty | 5 Years/10 Years | |
| the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | ||
| Grid Regulation | IEEE 1547.1, SRD V2.0 | |
| Safety / EMC Standard | FCC, UL 1741 | |